K Na Cl Ca PH Li Ref Electrodes For ISE Electrolyte Analyzer
The filling solution should be filled into the electrode with designated plastic bottle to avoid damage the membrane. The level of the filling solution should reach 2/3 height of the electrode inner chamber. Then fasten the electrode gap, shake the electrode till the air bubble goes out, dry the electrode body and install to the designated position.
Introduction
The filling solution should be filled into the electrode with designated plastic bottle to avoid damage the membrane. The level of the filling solution should reach 2/3 height of the electrode inner chamber. Then fasten the electrode gap, shake the electrode till the air bubble goes out, dry the electrode body and install to the designated position. A new electrode can be put in use immediately. Should it be unstable, please use fresh plasma to activate the electrodes till it reached stable status, it may take approximately 30-60 minutes.
Packing List
1801 K Electrode | 1pc |
1802 Na Electrode | 1pc |
1803 Cl Electrode | 1pc |
1804 Ca Electrode | 1pc |
1805 pH Electrode | 1pc |
1807 Ref Electrode | 1pc |
Features:
1. Rinsing Method: quickly rinsing solenoid valve, cleaning thoroughly electrode pipe;
2. Measuring Time: less than 50S (depends on electrode in stability);
3. Display: 5.6 inch Color Display touch screen;
4. Sensor: intelligent Sampling system, full automatic taking sample;
5. Parameters: K+, Na+, Cl-,Ca++,pH ,Li and Ref;
6. Temperature: 5-40 ℃, less than 85% relative humidity
7. Power Requirements: 220V±22V,50Hz±1Hz
Product Specifications:
Electrode | Range | Resolution | CV |
PH Hydrogen ion selective, flow-through electrode | 4-9mmol/L | 0.01mmo/L | <1% |
K potassium ion selective,flow-through electrode | 0.5-10mmol/L | 0.01mmo/L | <1% |
Na Sodium ion selective, flow-through electrode | 80-200mmol/L | 0.1mmo/L | <1% |
CL chloride ion selective, flow-through electrode | 50-200mmol/L | 0.1mmo/L | <1% |
CA calcium ion selective, flow-through electrode | 0.1-5mmol/L | 0.01mmo/L | <2% |
Li lithium ion selective, flow-through electrode | 0.3-3mmo/L | 0.01mmo/L | <2% |
Product Pictures

FAQ
Q1. What are your terms of packing?
A: The package of the electrode is individually packing, and put in neutral brown cartons of 430*360*440mm.
Q2. As for China Lab Five Items fully automatic Ise Electrolyte Analyzer, electrode & reagent inclding?
A: Yes, reagent ( Cal-1 & Cal-2 ) + elecctrode ( K, Na , Cl , Ca , Ci , Ph ).
Q3: How long does electrodes can be used?
A: Our electrodes are very good in quality, normally can use 1- 2 years. Some can maximum use for more than 5 years.
Q4: How do you make our business long-term and good relationship?
A: Firstly, we keep good quality and competitive price to ensure our customers benefit. Secondly, we respect every customer as our friend and we sincerely do business and make friends with them, no matter where they come from.
Hot Tags: k na cl ca ph li ref electrodes for ise electrolyte analyzer, China, manufacturers, factory, customized, wholesale, free sample
Semiauto Blood Serum ISE Electrolyte Analyzer Machine
Sterile Nylon Vagina Sample Collection Vagina Sampli...
Lab Glassware White Color Microscope Glass Cover Sli...
Chemical Glassware Graduated Borosilicate 250ml 500m...
13x75mm 8x120mm Vacuum Blood Collection ESR Tube PET...
Medical Disposable Polystyrene Westergren ESR Pipett...
Send Inquiry